LIMITED TIME - Free Shipping Over $69!

Authorized Zurn Distributor

Zurn - 1-710 - 1" Atmospheric Vacuum Breaker

Zurn  |  SKU: 1-710  |  Serving irrigation professionals and DIYers since 1981.
Brand New Factory Sealed Zurn Factory Warranty
$16499 each
 
Why so “cheap” at CheapSprinklers? Low prices by design — same parts, no compromise

Our prices are lower because of how we run our business — not because the product is different — and we pass those efficiencies directly on to you.

You’re receiving the same brand-new, factory-sealed item sold by big-box, supply-house, or bloated online-warehouse sellers — delivered direct to you, for less.

  • Bulk Purchasing: We buy in high volume to lower per-unit cost
  • Low Overhead: No physical storefronts or unnecessary middlemen
  • Price-First Model: Our business is built around keeping everyday prices as low as possible — so you can put the savings toward other projects or your business.
  • Fast & Efficient Fulfillment: Streamlined US warehouse operations keep costs down and orders moving fast.

The Result: Genuine products with full manufacturer warranty — delivered fast, without paying inflated big-box, supply-house, or bloated online-warehouse markups for the same parts.

CheapSprinklers Product Guarantee How we guarantee authenticity and warranty coverage

All products sold by CheapSprinklers are brand new and factory sealed. This Zurn Backflow Preventer (1-710) is sourced directly from Zurn and ships from us in new-in-box retail packaging.

We’ve been sourcing and supporting irrigation products for professionals and DIYers through both brick-and-mortar and online channels since 1981.

If there’s ever an issue, CheapSprinklers stands behind what we sell and will help coordinate any warranty claim or replacement.

  • Genuine New Zurn Backflow Preventer: no knockoffs, no refurbished, no old stock
  • Factory Sealed: shipped in original new-in-box retail packaging
  • Current Production Inventory: no discontinued or clearance stock
  • Complete Zurn Warranty: full manufacturer coverage begins when your order is delivered

The Result: Peace of mind. You’re installing top-quality equipment — and if there’s ever an issue with this Backflow Preventer, you’re fully supported by CheapSprinklers and Zurn.

1-710A - 1" Atmospheric Vacuum Breaker

The FEBCO Series 710 Atmospheric Vacuum Breakers are designed for use in multiple water applications such as:

  • Hose bibbs
  • Turf irrigation systems
  • Chemical vats
  • X-ray tanks
  • Laboratory sinks

Features / Benefits

  • 1'' FPT x FPT Connection
  • Bronze Body for Durability
  • Meets all specifications of ASSE
  • Documented flow curves established by The Twining Labs, Inc.
  • Simple service procedures.
  • Light weight plastic poppets.
  • Resilient rubber poppet discs designed for positive closure.
  • Cold water applications.
  • End Connections – NPT ANSI/ASME B1.20.1

Typical Installation

An Atmospheric Vacuum Breaker may be used to protect a crossconnection against backsiphonage, where the vacuum breaker is not subjected to back pressures due to pumps or any other conditions which may cause backpressure, no matter how slight. It must be installed on the discharge side of the last shutoff valve. Code requirements vary as to the height this vacuum breaker must be installed above the highest overflow level but a minimum of 6" (150mm) is required. The atmospheric vacuum breaker must be installed with the air inlet in a level position. 

Note: No valve of any type may be installed on the discharge side of an atmospheric vacuum breaker. Unit cannot have any shutoff downstream of it.

Operation

FEBCO Series 710 assures positive protection against backsiphonage of impure water into the main supply in the event that pressure loss causes vacuum conditions. A poppet seals the air inlet when the unit is pressurized. When a backsiphonage occurs, the poppet drops to allow air to enter the downstream piping. At the same time the poppet shields the water inlet to prevent foreign materials from entering the upstream piping. Restoration of pressure (flow) lifts the poppet to seal the air inlet.

Specifications

Atmospheric Vacuum Breakers shall be installed on the discharge side of the last shutoff valve, shall have all bronze bodies and bonnets, and shall be of the non-spilling type. Vacuum breaker shall be rated to 150psi (10.3 bar) working pressure and shall withstand water temperatures of 32ºF to 110ºF (0ºC - 43ºC) for the Series 710.

    Downloads

    Payment & Security

    Payment methods

    • Amazon
    • American Express
    • Apple Pay
    • Diners Club
    • Discover
    • Google Pay
    • Mastercard
    • PayPal
    • Shop Pay
    • Visa

    Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

    Zurn

    Zurn - 1-710 - 1" Atmospheric Vacuum Breaker

    $16499 each

    1-710A - 1" Atmospheric Vacuum Breaker

    The FEBCO Series 710 Atmospheric Vacuum Breakers are designed for use in multiple water applications such as:

    Features / Benefits

    Typical Installation

    An Atmospheric Vacuum Breaker may be used to protect a crossconnection against backsiphonage, where the vacuum breaker is not subjected to back pressures due to pumps or any other conditions which may cause backpressure, no matter how slight. It must be installed on the discharge side of the last shutoff valve. Code requirements vary as to the height this vacuum breaker must be installed above the highest overflow level but a minimum of 6" (150mm) is required. The atmospheric vacuum breaker must be installed with the air inlet in a level position. 

    Note: No valve of any type may be installed on the discharge side of an atmospheric vacuum breaker. Unit cannot have any shutoff downstream of it.

    Operation

    FEBCO Series 710 assures positive protection against backsiphonage of impure water into the main supply in the event that pressure loss causes vacuum conditions. A poppet seals the air inlet when the unit is pressurized. When a backsiphonage occurs, the poppet drops to allow air to enter the downstream piping. At the same time the poppet shields the water inlet to prevent foreign materials from entering the upstream piping. Restoration of pressure (flow) lifts the poppet to seal the air inlet.

    Specifications

    Atmospheric Vacuum Breakers shall be installed on the discharge side of the last shutoff valve, shall have all bronze bodies and bonnets, and shall be of the non-spilling type. Vacuum breaker shall be rated to 150psi (10.3 bar) working pressure and shall withstand water temperatures of 32ºF to 110ºF (0ºC - 43ºC) for the Series 710.

    Downloads
    View product